Diverters

Diverters Basic data: Plant: Off-Shore Gas turbine Flue GasCountry: NorwayInvestor: ALSTOM Power Norway ASDimensions: 2400 x 2400 mm Problem: ALSTOM Power Norway AS needed 3 diverters for service at off-shore gas turbine plants. They should be applicable for shut off in both end positions as well as for gas volume modulation purposes. Solution: We equipped …

Diverters Read More »

Diverters with ISO

Diverters with ISO Basic data: Plant: Diesel generator power stationCountry: TurkeyInvestor: BARMEK GAMMADimensions: 3462 x 3462 mm Problem: The aim was the design and supply of all flue gas dampers required for the Kirikkale Diesel – generator power station in Turkey, including 4 diverter dampers. Solution: We created our products according to ISO 9001 standards. …

Diverters with ISO Read More »

Diverter damper with special sealing

Diverter damper with special sealing Basic data: Plant: Combined cycle power stationCountry: AustriaInvestor: BABCOCK POWER AE – GrazDimensions: 5020 x 4640 mm Problem: The diverter was needed for the combined cycle power station at LINZ, AUSTRIA. The structure should be resilient and tight during extremely high temperatures and high pressure differentials. Solution: We applied not …

Diverter damper with special sealing Read More »

Tandem Louver Damper

Tandem Louver Damper Basic data: Plant: FGD and DeNOx PlantCountry: AustriaInvestor: ABB UMWELTTECHNIK BUTZBACHDimensions: 4700 x4700 mm Problem: The Customer needed the design and supply of all shut off and modulation dampers for the new FGD and DeNOx plant of the Theiss powerstation. All the dampers should be extremely tight to prevent gas leakages. Solution: …

Tandem Louver Damper Read More »

Diverter dampers

diverter dampers Basic data: Plant: FGD plantsCountry: TurkeyInvestor: BABCOCK BORSIG POWER – Austrian ENergyDimensions: 4000×5000 mm Problem: Supply of all required modulation and shut-off dampers for boilers 3 & 4 of the CAYIRHAN power station. The specific dampers must meet the most stringent accident prevention regulations (U V V), making gas leakage impossible. Solution: Among …

Diverter dampers Read More »

4-way damper

4-way damper Basic data: Plant: Diesel generator plantCountry: TurkeyInvestor: BARMEK GAMADimensions: 2500 mm Problem: The aim was to supply all shut off dampers required for the Diesel generator plants of the KIRIKKALE power station in Turkey, including 4-way diverter. Solution: The operation of the damper is possible by usage of a pneumatic actuator with spring …

4-way damper Read More »